Prehearing Disclosure Statement Packet.pdf
2026A-02786-CHC-ROC · Registrar of Contractors · 2026-07-26
EG4® 12kPV HYBRID INVERTER The EG4 12kPV is a 48V split-phase, hybrid inverter/charger capable of utilizing 12kW of PV input and efficiently outputting 8kW of power while also charging your battery bank. Parallel up to 10 units for 80kW of output power and control multiple stations and units using the new EG4 monitoring software.
HIGH REMOTE FREQUENCY 10-YEAR ADJUSTMENT SPLIT-PHASE WARRANTY VIA EG4 DESIGN SOFTWARE
ALL-IN-ONE HYBRID INVERTER Capable of running entirely off the grid, using grid electricity, or selling power back to the grid.
UP TO 600VDC INPUT The extra high voltage enables lower cable sizing for the 2 MPPTs and a maximum recommended PV input of 15kW, eliminating the need for a combiner box.
PLUG IN WI-FI DEVICE Enables wireless connection between our new monitoring platform and the 12kPV through the EG4 app or EG4 Monitor system.
CLOSED-LOOP COMMUNICATIONS Able to communicate with EG4 48V batteries and other battery brands. A battery firmware update is required for closed-loop communications with LifePower4 batteries.
RAPID SHUT DOWN The 12kPV is CSA C22.2#330:2017 and NEC 690.12 ready with its built-in RSD capabilities.
©2025 EG4® ELECTRONICS, LLC. ALL RIGHTS RESERVED. VERSION 1.0.5 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE. MODEL #: IV-8000-HYB-AW / IV-8000-HYB-AW-00 T E C H N I C A L S P E C I F I C A T I O N S AC INPUT DATA NOMINAL AC VOLTAGE 120/240VAC; 120/208VAC (L1/L2/N required) FREQUENCY 50/60Hz MAX. AC INPUT POWER 8000W MIN. GENERATOR SIZE >5000W MAX. GEN | GRID PASSTHROUGH CURRENT 80A | 80A AC GRID OUTPUT DATA MAX. OUTPUT CURRENT 33.3A@240VAC | 38.5A @208VAC OUTPUT VOLTAGE 120/240VAC; 120/208VAC NOMINAL POWER OUTPUT 8000W OUTPUT FREQUENCY 50/60Hz POWER FACTOR 0.99 @ Full Load REACTIVE POWER ADJUST RANGE ±0.8 MAX CONT. LINE WATTAGE 4000W 0.5 s 1s 1 min 12 min PEAK POWER 16kW 12kW 10kW 8.8kW OPERATING FREQUENCY 50/60Hz THD (V) @FULL LOAD <3% Single Parallel TRANSFER TIME ms – Default, 10 ms – Selectable 20 ms PV INPUT DATA NUMBER OF MPPTS 2 INPUTS PER MPPT 2 25/25A MAX. USABLE INPUT CURRENT 25A per MPPT | 41.6A in total MAX. SHORT CIRCUIT INPUT CURRENT 31/31A DC INPUT VOLTAGE RANGE 100-600 VDC UNIT STARTUP VOLTAGE 100 VDC MPPT OPERATING VOLTAGE RANGE 120-500 VDC NOMINAL MPPT VOLTAGE 360 VDC MAXIMUM UTILIZED SOLAR POWER 12000W RECOMMENDED MAXIMUM SOLAR INPUT 15000W EFFICIENCY MAXIMUM EFFICIENCY (PV TO GRID) 97.5% MAXIMUM EFFICIENCY (BATTERY TO GRID) 94% CEC WEIGHTED EFFICIENCY 96.4% MAXIMUM EFFICIENCY (PV TO BATTERY) 99.9% IDLE CONSUMPTION (STANDBY MODE) <55W BATTERY DATA COMPATIBLE BATTERY TYPES Lead-Acid/Lithium MAX. CHARGE/DISCHARGE CURRENT 167A @ 48 VDC NOMINAL VOLTAGE 48 VDC VOLTAGE RANGE 40-60 VDC (Lithium); 40-60 VDC (Lead-Acid) RECOMMENDED BATTERY CAPACITY PER INVERTER >200Ah GENERAL DATA MAX. UNITS IN PARALLEL 10 PRODUCT DIMENSIONS (H×W×D) 29.5×20.5×11.2 in (750×520×285 mm) UNIT WEIGHT 110 lbs. (50 kg) DESIGN TOPOLOGY High Frequency - Transformerless RELATIVE HUMIDITY 0-100% OPERATING ALTITUDE <2000m (<6561 ft) OPERATING AMBIENT TEMPERATURE RANGE -13°F – 140°F (-25°C – 60°C) STORAGE AMBIENT TEMPERATURE RANGE -13°F – 140°F (-25°C – 60°C) NOISE EMISSION (TYPICAL) <50 dB @ 3 ft LOCKED ROTOR AMPS (LRA) 195A COMMUNICATION INTERFACE RS485/Wi-Fi/CAN STANDARD WARRANTY* 10-year standard warranty ENCLOSURE RATING NEMA 4X PV Arc Fault Protection, PV Ground Fault Protection, PV Reverse SAFETY FEATURES Polarity Protection, Pole Sensitive Leakage Current Monitoring Unit, Surge Protection Device, integrated PV disconnect STANDARDS AND CERTIFICATIONS UL1741 SB CSA C22.2#107.1:2016 CSA C22.2#330:2017 ED. 1 HECO SRD-IEEE-1547.1:2020 ED. 2 RAPID SHUT DOWN (RSD) NEC 2020:690.12 FCC PART 15, CLASS B *For information regarding warranty registration on EG4® Electronics products, please navigate to https://eg4electronics.com/warranty/ and select the corresponding product to begin the registration process. CHANGELOG V1.0.4 Modified max AC input power from 12000 to 8000W V1.0.3 3-10-25 - Added Locked Rotor Amps value to specifications 12-30-24 Removed (Pending) from FCC Part 15 cert 11-15-24 Published v1.0.2 Removed IP rating and added NEMA 4X rating Modified warranty information WALLMOUNT ALL WEATHER LITHIUM BATTERY The EG4® WallMount All Weather 280Ah batteries are ideal for low-voltage residential outdoor energy storage system (ESS) applications. The batteries use lithium iron phosphate cells with the highest safety performance and an intelligent Battery Management System (BMS) that can monitor and record the voltage of each cell along with the current, voltage, and temperature of the module in real-time. The BMS also contains a passive balance function and an advanced battery control method, both of which improve the performance and longevity of the battery pack.
82.6MWh *10 YEAR B U I LT- I N I N T E G R AT E D WARRANTY LIFETIME 200A BMS 600A BUSBARS >8000 CYCLES @ PRODUCTION* 80% DOD ON-BOARD LCD TOUCH SCREEN Easy to see BMS monitoring, and selectable closed-loop communications with EG4, Schneider, Sol-Ark, Victron, Growatt, Megarevo, Luxpower, and Deye inverters.
DUAL ON-BOARD FIRE ARRESTORS -safe protection against thermal runaway.
WEATHER-TIGHT QUICK CONNECTS Included battery cables with outdoor rated connectors allowing for fast, safe, and reliable battery connections.
INTEGRATED SELF-HEATING FEATURE Heats the battery when the ambient temperature is low. A key feature for outdoor Lithium battery cell operations.
INTEGRATED BUSBARS The battery design comes manufactured with 600A internal busbars with multiple terminals (4 positive & 4 negative) eliminating the need for external busbars when paralleling batteries and/or multiple inverters.
INNOVATIVE EMERGENCY STOP FUNCTION The optional ESS disconnect can shut down all batteries and inverters (if equipped with rapid shut down capability) with the press of a button.
THE PERFECT PARTNER TO THE EG4 18kPV The optional conduit box mates up directly to the connection ports of the inverter allowing a sleek installation. For other inverters or stand-alone battery installation, the conduit box plugs should be installed. *For information regarding warranty registration on EG4® Electronics ©2025, EG4® ELECTRONICS, LLC. ALL RIGHTS RESERVED. products, please navigate to https://eg4electronics.com/warranty/ VER. 1.1.8 | INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE. and select the corresponding product to begin the registration MODEL #: WP-16/280-1AWLL | WP-16/280-1-AWLL process. S P E C I F I C AT I O N S H E E T MODULE OPERATING PARAMETERS Parameter BMS Recommended Charger Settings Total Energy Capacity 14.3kWh @25C, 100% SOC - Voltage 51.2V - Capacity 280Ah ±2% @25°C ±2°C @ 0.5C Charging Voltage (Bulk/Absorb) 56.0V (±0.8V) 56.2V (±0.2V) Float - 54V (±0.2V) SOC - 20%* Charge Current 140A Max. Continuous 60 – 140A Discharge Current 140A Max. Continuous 60 – 140A BMS PARAMETERS Charge Spec Delay Recovery Cell Voltage Protection 3.8V 1 sec 3.45V Module Voltage Protection 60V 1 sec 55.2V Charge Over-Current 1 >205A 10 sec - Charge Over-Current 2 >225A 3 sec - <23°F or >158°F >32°F or <140°F Temperature Protection 1 sec <-5°C or >70°C >0°C or <60°C Discharge Spec Delay Recovery Cell Voltage Protection 2.3V 1 sec 3.1V Module Voltage Protection 44.8V 1 sec 48V Discharge Over-Current 1 >205A 10 sec 60 sec Discharge Over-Current 2 >300A 3 sec 60 sec Short Circuit >600A <0.1 ms - <-4°F or >167°F >14°F or <149°F Temperature Protection 1 sec <-20°C or >75°C (>-10°C or <65°C) PCB Temperature Protection >230°F (>110°C) 1 sec @ <176°F (<80°C) GENERAL SPECIFICATIONS Parameter Spec Condition Cell Balance 120mA Passive Balance >40mV Measure Range: Temperature Accuracy 3% Cycle Measurement -40°F – (-40°C – Voltage Accuracy 0.5% Cycle Measurement Cells & Module Measure Range: Current Accuracy 3% Cycle Measurement -200 – 200A SOC 5% Integral Calculation Power Consumption <300uA Standby/Storage (Standby) Power Consumption <25mA Charging/Discharging (Operating) Communication Ports RS485/CAN Customizable *EG4 recommends this value be set no lower than 20% to maintain the recommended 80% depth of discharge. BATTERY HEATER SPECIFICATIONS Parameter Spec Condition Voltage 56V - Power Consumption 224W - Internal Battery Temperature or ENVIRONMENTAL PARAMETERS Charging Range 32°F 22 50°C) Discharging Range - 31°F (- 5°C) Storage Range 32 13 45°C) Operating Altitude <16404 ft. (<5000 m) Ingress Protection IP65 PHYSICAL SPECIFICATIONS Dimensions (H × W × D) 36.2 × 20.2 × 9.1 in. (92 × 51.2 × 23.2 cm) Weight 308.6 lbs. (140 kg) Design Life >15 years Cycle Life >8000 Cycles @ 0.5C 80% DOD Lifetime Production 82.6MWh** SAFETY CERTIFICATIONS cations UL1973, UL9540A (Passed) **(51.2V×280Ah/1000×80%×8000 cycles/1000)90%=MWh CHANGELOG Version 1.1.8 operating altitude into environmental parameters Version 1.1.7
– 140A
Version 1.1.6 – 160A to 60 – 140A. Version 1.1.5 Added operating altitude range value Version 1.1.3
Version 1.1.0 Reformatted document to match template standards. Adjusted the short circuit current rating from 600A to 2000A. Version 1.0.2 Added Total Energy Capacity to table Version 1.0.1 Added QR Codes Version 1.0.0 First revision of spec sheet QuickMount® Halo UltraGrip
RD STRUCTURAL SCREW PN RD-1430-01-M1 SOLD SEPARATELY SHOWN FOR REFERENCE
Release Liner shown for reference
ITEM NO DESCRIPTION QTY IN KIT QM Halo UltraGrip(Mill or Black) 1
PART NUMBER DESCRIPTION QM-HUG-01-M1 Halo UltraGrip - Mill QM-HUG-01-B1 Halo UltraGrip - Black
© 202 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information. QM-HUG-01-B1 or QM-HUG-01-M1 Cut Sheet Rev 1.0 1. Halo UltraGrip .38
3.35
3.83
.40
.26
1.63 1.56
.34
3.00
Property Value Material 300 Series Aluminium Finish Mill or Black
© 202 IronRidge, Inc. All rights reserved. Visit www.ir-patents.com for patent information. QM-HUG-01-B1 or QM-HUG-01-M1 Cut Sheet Rev 1.0 NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SOLARHOOKS INSTALLATION GUIDE. 2. PACKAGING: KITS OF 20 3. RAIL CONNECTION HARDWARE, T-BOLTS OR RAIL CLAMPS, ARE SOLD SEPARATELY. SEE 009020S AND SHCLMPM2 & SHCLMPD2
2X - .25 X 3.5" SS HEX HEAD LAG BOLTS W/ SS EPDM BONDED WASHERS 3/16"
15/16" 6"
9"
3/8"
1/8" 5/16" 7/8" 6 1/2" 1 5/8"
15/16"
PART # TABLE P/N DESCRIPTION 004CT2H SOLARHOOK SPANISH 9" BASE
PRODUCT LINE: SOLARHOOK DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: PART DETAIL NOMINAL 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA DESCRIPTION: SPANISH 9" BASE PRODUCT PROTECTED BY PHONE: 505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 5/1/2024 LEGAL NOTICE SHEET NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SOLARHOOKS INSTALLATION GUIDE. 2. PACKAGING: KITS OF 30 3. RAIL CONNECTION HARDWARE, T-BOLTS OR RAIL CLAMPS, ARE SOLD SEPARATELY. SEE 009020S AND SHCLMPM2 & SHCLMPD2
2X - .25 X 3.5" SS HEX HEAD LAG BOLTS W/ SS EPDM BONDED WASHERS
1/8"
3/16"
1/2" SQUARE NECK CARRIAGE BOLT, SS
5/16-18 SERRATED FLANGE LOCKNUT 1/16"
3/8"
3/4" 3 3/4"
11/16" 7 13/16"
9/16" 5/16"
1/2"
PART # TABLE P/N DESCRIPTION 004CT5H SOLARHOOK UNIVERSAL
PRODUCT LINE: SOLARHOOK DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: ASSEMBLY DETAIL NOMINAL 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA DESCRIPTION: UNIVERSAL PRODUCT PROTECTED BY PHONE: 505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 5/1/2024 LEGAL NOTICE SHEET NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SOLARHOOKS INSTALLATION GUIDE. 2. PACKAGING: KITS OF 30 3. RAIL CONNECTION HARDWARE, T-BOLTS OR RAIL CLAMPS, ARE SOLD SEPARATELY. SEE 009020S AND SHCLMPM2 & SHCLMPD2
2X - .25 X 3.5" SS HEX HEAD LAG BOLTS W/ SS EPDM BONDED WASHERS
3/8" 3/8 X 1 1/2" SLOT
3/16"
9/16"
7/16" 2 7/16" SERRATIONS 2 13/16" 3/8 X 1 1/2" SLOT
1/16"
3/16" 3/8" 3/8" ADJUSTMENT
PART # TABLE P/N DESCRIPTION 004AST1 SOLARHOOK ADJ STONE COATED
PRODUCT LINE: SOLARHOOK DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: PART DETAIL NOMINAL 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA DESCRIPTION: ADJ STONE COATED PRODUCT PROTECTED BY PHONE: 505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 5/1/2024 LEGAL NOTICE SHEET NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SOLARHOOKS INSTALLATION GUIDE. 2. PACKAGING: KITS OF 30 3. RAIL CONNECTION HARDWARE, T-BOLTS OR RAIL CLAMPS, ARE SOLD SEPARATELY. SEE 009020S AND SHCLMPM2 & SHCLMPD2
2X - .25 X 3.5" SS HEX HEAD LAG BOLTS W/ SS EPDM BONDED WASHERS
6X 3/8"
3/8"
3/4" 7/16" 15/16" 1/2"
7/8" 15/16" 11/16"
3/4"
15/16" 1 3/16"
PART # TABLE P/N DESCRIPTION 004ST1S SOLARHOOK STONE COATED MT ST1
PRODUCT LINE: SOLARHOOKS DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: PART DETAIL NOMINAL 1411 BROADWAY BLVD. NE STONE COATED PRODUCT PROTECTED BY ALBUQUERQUE, NM 87102 USA DESCRIPTION: PHONE: 505.242.6411 MT ST1 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 5/1/2024 LEGAL NOTICE SHEET NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SOLARHOOKS INSTALLATION GUIDE. 2. PACKAGING: KITS OF 30
9"
1'-2"
5/8" 13/16" 3"
PART # TABLE P/N DESCRIPTION 004FLCT SOLARHOOK SPANISH FLCT
PRODUCT LINE: SOLARHOOK DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: PART DETAIL NOMINAL 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA DESCRIPTION: SPANISH FLCT PRODUCT PROTECTED BY PHONE: 505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 5/1/2024 LEGAL NOTICE SHEET NOTES: 1. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH SOLARHOOKS INSTALLATION GUIDE. 2. PACKAGING: KITS OF 30
9"
1'-0"
13/16"
3/8" 4 1/8"
PART # TABLE P/N DESCRIPTION 004FLAT SOLARHOOK AT - ST FLASHING
PRODUCT LINE: SOLARHOOK DRAWING NOT TO SCALE ALL DIMENSIONS ARE DRAWING TYPE: PART DETAIL NOMINAL 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA DESCRIPTION: AT - ST FLASHING PRODUCT PROTECTED BY PHONE: 505.242.6411 ONE OR MORE US PATENTS WWW.UNIRAC.COM REVISION DATE: 5/1/2024 LEGAL NOTICE SHEET [email redacted] 276-220-0064 http://www.evengineersnet.com 6/26/2025
RE: Structural Certification for Installation of Residential Solar JENNIFER AKERBERG:3985 N BEAR CREEK LANE, CASA GRANDE, AZ 85122
Attn: To Whom It May Concern
This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. From the field observation report, the roof is made of Composition shingle roofing over roof plywood supported by 2X6 Rafters at 24 inches. The slope of the roof was approximated to be degrees.
After review of the field observation data and based on our structural capacity check, Existing roof framing have been determined to be adequate to support the imposed loads without structural upgrades. Capacity calculations were done in accordance with applicable building codes.
Design Criteria Code 2018 International Building Code (ASCE 7-16) Risk category II Wind Load (component and Cladding) Roof Dead Load Dr 10 psf V 115 mph PV Dead Load DPV 3 psf Exposure C Roof Live Load Lr 20 psf Ground Snow S 0 psf
If you have any questions on the above, please do not hesitate to call.
Signed: 6/26/2025 Sincerely,
Vincent Mwumvaneza, P.E. EV Engineering, LLC [email redacted] http://www.evengineersnet.com [email redacted] 276-220-0064 http://www.evengineersnet.com
Structural Letter for PV Installation
Date: 6/26/2025 Job Address: 3985 N BEAR CREEK LANE CASA GRANDE, AZ 85122 Job Name: JENNIFER AKERBERG Job Number: 250626JA
Scope of Work This Letter is for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications.
Table of Content Sheet Cover Attachment checks Snow and Roof Framing Check Seismic Check and Scope of work
Engineering Calculations Summary Code 2018 International Building Code (ASCE 7-16) Risk category II Roof Dead Load Dr 10 psf PV Dead Load DPV 3 psf Roof Live Load Lr 20 psf Ground Snow S 0 psf Wind Load (component and Cladding) V 115 mph Exposure C
References NDS for Wood Construction
Signed: 6/26/2025
Sincerely,
Vincent Mwumvaneza, P.E. EV Engineering, LLC [email redacted] http://www.evengineersnet.com [email redacted] 276-220-0064 http://www.evengineersnet.com Wind Load Cont. Risk Category = II Wind Speed (3s gust), V = 115 mph ASCE 7-16 Figure 26.5-1B Exposure = C KZt = 1.0 ASCE 7-16 Sec 26.8.2 KZ = 0.85 ASCE 7-16 Table 26.10-1 Kd = 0.85 ASCE 7-16 Table 26.6-1 Ke = 0.95 ASCE 7-16 Table 26.9-1 qh= 0.00256KzKztKdKeV = 23.15 psf Pitch = 24.0 Degrees E= 1.5 Conservatively assuming all exposed a= 0.8 conservatively assuming 10 ft effective area
Uplift (W) Zone(1,2e) Zone(2r, 2n) Zone(3e) Zone(3r) Fig. 30-3-2 GCp= -1.3 -1.7 -1.7 -1.8 Eq. 29.4-7 P=qh(GCp)( E)( a)= -36.11 -47.22 -47.22 -49.99
GCp= 0.6 Figure 30.3-2 P=qh(GCp)( E)( a)= 16.66 Equation 29.4-7
Rafter Attachments: 0.6D+0.6W (CD=1.6) Connection Check Attachement max. spacing= 4 ft 5/16" Lag Screw Withdrawal Value= 266 lbs/in Table 12.2A - NDS Lag Screw Penetration= 2.5 in DFL Assumed Prying Coefficient= 1.4 Allowable Capacity= 760 lbs Zones Trib Width Area (ft) Uplift (lbs) Down (lbs) Zone(1,2e) 4 11.0 154.9 143.0 Zone(2r, 2n) 4 11.0 198.9 143.0 Zone(3e) 4 11.0 198.9 143.0 Zone(3r) 4 8.3 157.4 143.0 Conservative Max= 198.9 < 760 CONNECTION IS OK 1. Pv seismic dead weight is negligible to result in significant seismic uplift, therefore the wind uplift governs [email redacted] 276-220-0064 http://www.evengineersnet.com Vertical Load Resisting System Design Roof Framing Rafters Snow Load Fully Exposed pg= 0 psf Ce = 0.9 Ct = 1.1 Is = 1.0 pf = 0 psf pfmin. = 0.0 psf ps = 0 psf
Max Length, L = 9.0 ft (Beam maximum Allowable Horizontal Span) Tributary Width, WT = 24 in Dr = 10 psf 20 plf PvDL = 3 psf 6 plf Load Case: DL+0.75(0.6W+S) (CD=1.6) 0.75(Pnet+Ps)+ Ppv DL= 40 plf Mdown= 364 lb-ft Mallowable = Sx x Fb' (wind)= 1357 lb-ft > 364 lb-ft OK Load Case: DL+S (CD=1.15) Ps+ Ppv DL= 25 plf Mdown= 229 lb-ft Mallowable = Sx x Fb' (wind)= 975 lb-ft > 229 lb-ft OK Load Case: DL+0.6W (CD=1.6) Pnet+ Ppv DL= 45.5 plf Max Moment, Mu = 409 lb-ft Mallowable = Sx x Fb' (wind)= 1357 lb-ft > 409 lb-ft OK Pv max Shear= 143.0 lbs Shear, Vu=wL/2+Pv Point Load = 260 lbs Max Shear, Vu=wL/2+Pv Point Load = 260 lb Member Capacity DF-L No.2 2X6 Design Value CL CF Ci Cr KF Adjusted Value Fb = 900 psi 1.0 1.3 1.0 1.15 2.54 0.85 0.8 1346 psi Fv = 180 psi N/A N/A 1.0 N/A 2.88 0.75 0.8 180 psi E= 1600000 psi N/A N/A 1.0 N/A N/A N/A N/A 1600000 psi Emin = 580000 psi N/A N/A 1.0 N/A 1.76 0.85 N/A 580000 psi Depth, d = 5.5 in Width, b = 1.5 in Cross-Sectonal Area, A = 8.25 in Moment of Inertia, Ixx = 20.7969 in Section Modulus, Sxx = 7.5625 in Allowable Moment, Mall = Fb'Sxx = 847.9 lb-ft DCR=Mu/Mall = 0.29 < 1 Satisfactory Allowable Shear, Vall = 2/3Fv'A = 990.0 lb DCR=Vu/Vall = 0.26 < 1 Satisfactory [email redacted] 276-220-0064 http://www.evengineersnet.com Siesmic Loads Check Roof Dead Load 10 psf % or Roof with Pv 32.06% Dpv and Racking 3 psf Average Total Dead Load 11.0 psf Increase in Dead Load 3.8% OK
The increase in seismic Dead weight as a result of the solar system is less than 10% of the existing structure and therefore no further seismic analysis is required.
Limits of Scope of Work and Liability
We have based our structural capacity determination on information in pictures and a drawing set titled PV plans - JENNIFER AKERBERG. The analysis was according to applicable building codes, professional engineering and design experience, opinions and judgments. The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural analysis standards and procedures.