2023A-10983-CHC-ROC Notice of Hearing and Packet MAILED

2023A-10983-CHC-ROC · Registrar of Contractors · 2024-02-28

REGISTRAR OF CONTRACTORS OF THE STATE OF ARIZONA

Michael Gulas , Case No. 2023-10983 COMPLAINANT, Docket No. 2023A-10983-CHC-ROC v. NOTICE OF HEARING ON CONTESTED CASE R & D Appel LLC, DBA: The Edge Remodeling, License No. ROC 237727, 349555 RESPONDENT.

This Notice of Hearing is issued under A.R.S. § 41-1092.05(D).

HEARING INFORMATION The hearing is set for:

April 12, 2024 1:00 PM Tammy Eigenheer Google Meet. A link will be provided directly from The Office of Administrative Hearings. Go to www.azoah.com to request to appear in-person.

If you have requested to appear in-person at the hearing, the hearing will

be held at 1740 W Adams Street, Phoenix, AZ 85007.

You must attend this hearing. This is an adversarial hearing before an administrative law judge, and is conducted in a similar manner as judicial proceedings. Thus, you must be prepared to present evidence, including witness testimony and documents, in support of your case.

STATEMENT OF LEGAL AUTHORITY AND JURISDICTION The State of Arizona has determined that the licensing and regulation of construction contractors is a proper state function, and has vested authority in the Registrar of Contractors

to administer Title 32, Chapter 10 of the Arizona Revised Statutes. A.R.S. §§ 32-1101 et seq.

All hearings for alleged violations of Title 32, Chapter 10 are conducted under Title 41,

Chapter 6, Article 10. A.R.S. § 32-1156.

The statutes and rules governing the hearing can be found at: Arizona Revised Statutes §§ 41-1092 to -1092.12, and Arizona Administrative Code R2-19-101 to -122. PARTICULAR ARIZONA STATUTES AND RULES INVOLVED The statutes and rules the Respondent is alleged to have violated are cited in the complaint and citation, which were served on the Respondent on February 1, 2024.

SHORT AND PLAIN STATEMENT OF THE MATTERS ASSERTED The complaint and citation allege that the Respondent committed the following act(s):

Charge: 1 A.R.S. § 32-1154(A)(3) - R4-9-108(a)

Charge: 2 A.R.S. § 32-1154(A)(22)

THE PARTIES TO THE ADMINISTRATIVE HEARING Because Respondent is a licensee and is charged with an act(s) or omission(s) that is

cause for the suspension or revocation of a license, Respondent is a party to this case and will

be a party to the hearing.

Because Complainant alleged Respondent committed an act(s) or omission(s) that is cause for the suspension or revocation of a license, Complainant is a party to this case and will be a party to the hearing. Respondent and Complainant, as the parties to the hearing, will present evidence and argument to the administrative law judge. The Registrar’s assigned investigator will appear as a witness at the hearing.

RIGHT TO BE REPRESENTED The parties to the administrative hearing may choose to be represented by an attorney. A.R.S. § 41-1092.07(B). If one of the parties is a company, the company may be represented

by an officer or employee if that person satisfies the conditions set forth in A.R.S. § 32-

1156(B).

CHANGE OF ADDRESS Each party must inform the Registrar and the Office of Administrative Hearings of

any change of address within five (5) days of the change. A.R.S. § 41-1092.04.

HEARING PROCEDURES AND RULES The administrative hearing will be conducted in accordance with A.R.S. §§ 41-1092

to -1092.12, and A.A.C. R2-19-101 to -122. The parties should review the statutes, rules, and processes governing the administrative hearing. Copies of the statutes, rules, and articles

regarding the administrative hearing process can be found at https://www.azoah.com/.

REGISTRAR’S APPEARANCE BY VIDEO CONFERENCE OR TELEPHONE

The Registrar’s investigators, employees, and attorneys will appear at the hearing via

video conference or telephone unless requested by a party to appear in-person. Requests for

the Registrar’s investigators, employees, or attorneys to appear in-person must be filed with the Registrar and the Office of Administrative Hearings no later than seven (7) calendar days prior to the hearing date.

HEARING PACKET In the interests of administrative efficiency, the Registrar compiles and discloses certain documents to the parties and the Office of Administrative Hearings. These documents are attached to this Notice of Hearing as the “Hearing Packet.” If any party wishes to submit additional evidence, they must do so during the hearing after completing a disclosure statement. See “Disclosure Statement” section below.

SUBPOENAS FOR TESTIMONY FROM A WITNESS OR DOCUMENTS The parties to the hearing must be prepared to present evidence in support of their case. If a party wants to obtain testimony from a witness or documents not in the party’s possession, the party must prepare and file a written subpoena for the Administrative Law Judge to review and sign, if approved. A.R.S. § 41-1092.07(C). Forms for requesting a subpoena can be found on the Office of Administrative Hearings’ website at www.azoah.com. The party seeking a subpoena must serve notice on all the parties to the hearing, and on the Registrar. A.R.S. § 41-1092.04.

DISCLOSURE STATEMENT At least seven calendar days before the hearing, each party must prepare and serve a

disclosure statement on all other parties, and file it with the Office of Administrative Hearings.

A.A.C. R4-9-118; A.A.C. R2-19-108. The disclosure statement must include any exhibit the

party will use at the hearing. A party’s failure to timely disclose any witness or exhibit, without good cause, may result in the administrative law judge excluding those witnesses or exhibits from being used at the hearing. A.A.C. R4-9-118(C). A sample disclosure form is available on the Registrar’s website at https://roc.az.gov/forms/RC-L-800A%20- %20Prehearing%20Disclosure%20Statement%2020191007v4.pdf

CHANGING THE HEARING DATE The date of the hearing may only be advanced or delayed on the agreement of the

parties or on a showing of good cause. A.R.S. § 41-1092.05(C). The date of the hearing may

be changed by filing a written agreement of the parties to change the date of the hearing. The

written agreement must be filed with the Office of Administrative Hearings, directed to the

assigned Administrative Law Judge, and transmitted to the Registrar and all other parties. The

assigned Administrative Law Judge may be found on the Office of Administrative Hearings’ web portal at www.azoah.com If a party would like to move the date of the hearing without agreement of all parties, the party must file a written motion with the Office of Administrative Hearings, directed to the assigned Administrative Law Judge, and transmit a copy to the Registrar and all other parties.

The motion must state in detail good cause for why the date of the hearing should be advanced or delayed, and the position of all other parties regarding the advancement or delay. A party may also file a motion asserting a right to an expedited hearing upon a showing of extraordinary circumstances or the possibility of irreparable harm. A.R.S. § 41-1092.05(E).

RESOLUTION SHORT OF ADJUDICATION In any case which is resolved or settled by the parties, or which is withdrawn by the Complainant without objection from Respondent after the Notice of Hearing is issued, the parties must notify the Office of Administrative Hearings of the resolution or settlement. Any such cases will be listed on the Registrar’s website and its records under the category: “Closed Complaints – Resolved/Settled/Withdrawn.” Dated February 28, 2024.

By: /s/ Erika Hoskin Erika Hoskin Legal Secretary Legal Department Arizona Registrar of Contractors Copy mailed via USPS First Class mail February 28, 2024 to: Respondent(s) R & D Appel LLC DBA: DBA: The Edge Remodeling, 21600 S Crismon Rd Queen Creek, AZ 85142

Complainant(s) Michael Gulas 19352 E Thornton Rd Queen Creek, AZ 85142

Copy sent electronically this same date to:

Respondent at email address on record with the Registrar Complainant at email address on record with the Registrar

Case No. 2023-10983 /

Katie Hobbs, Governor Martin Quezada, Director

Hearing Packet FAQ What is the Hearing Packet?

The Hearing Packet is a packet of certain documents collected or issued by the Registrar over the course of its investigation.

Who gets the Hearing Packet?

The Hearing Packet is assembled and distributed to all parties and to the Office of Administrative Hearings (“OAH”) prior to an administrative hearing.

What types of cases does the Registrar prepare a Hearing Packet for?

The Registrar prepares a Hearing Packet for Complainant-Handled Cases and No-Pay Cases. Note: If the Docket Number on the Notice of Hearing contains a “CHC” or “NPC”, your case is a Complainant-Handled Case or a No-Pay Case.

What is in the Hearing Packet?

The Hearing Packet contains essential case-specific documents and at a minimum will include the following documents:

● Original complaint;

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Within AZ 877.692.9762 · Fax 602.542.1599 · roc.az.gov Hearing Packet FAQ

Katie Hobbs, Governor Martin Quezada, Director

● Citation; and ● Answer.

The Hearing Packet will also contain the following documents (if applicable):

● Jobsite inspection notices, notes, and photos; ● Written directives; and ● Compliance inspection notices, notes, and photos.

What if there are documents missing from the Hearing Packet?

If there is any evidence you submitted to the Registrar that are not included in the Hearing Packet it is your responsibility to introduce that evidence at the administrative hearing. Note: The administrative law judge assigned to your case does not have access to the entire Registrar record.

If there is additional evidence you submitted to the Registrar during the investigation that you also want to introduce as evidence during your hearing, it is your responsibility to:

● Properly disclose that evidence to the other party; and ● Introduce the evidence during your hearing.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Within AZ 877.692.9762 · Fax 602.542.1599 · roc.az.gov Hearing Packet FAQ

Katie Hobbs, Governor Martin Quezada, Director

How do I disclose evidence I intend to use at a Hearing?

You must properly disclose any and all documents and witnesses you intend to use at your hearing according to the Registrar’s Prehearing Disclosure Rules. See Arizona Administrative Code Section R4-9-118.

A sample prehearing disclosure form and instructions are provided to the parties by the Registrar.

How do I obtain documents I previously submitted to the Registrar?

If you previously submitted documents to the Registrar and need a copy of these documents, please contact the Registrar’s Legal Department or submit a public records request at https://roc.force.com/AZRoc/s/roc-public-request.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Within AZ 877.692.9762 · Fax 602.542.1599 · roc.az.gov Hearing Packet FAQ

Complainant: Michael Gulas 19352 E Thornton Rd Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 Respondent: R & D Appel LLC DBA: The Edge Remodeling 21620 E Nightingale Dr Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 September 26, 2023

Jobsite Inspection Notice Re: Complaint Number 2023-10983

Dear Complainant and Respondent:

A formal complaint has been filed with the Arizona Registrar of Contractors.

A jobsite inspection is scheduled for October 16, 2023 at 10:00 AM. The Complainant is required to be present. The Respondent’s attendance is requested and encouraged. The Registrar encourages both parties to make a good faith effort to resolve this complaint prior to the jobsite inspection.

COMPLAINANT: 1. Under A.R.S. § 32-1155(D)(1), the Respondent must be allowed, upon request, the opportunity to inspect the work complained of within fifteen (15) days of receiving this notice. If Respondent is not provided an opportunity to inspect the work within the fifteen (15) day time period, the Registrar may be prohibited from taking further action on this complaint. 2. The Registrar may also be precluded from taking further action on this complaint, if the work that is the subject of the complaint is subject to neglect, modification, or abnormal use. A.R.S. § 32-1155(D)(2) 3. You must provide safe access to any area to be inspected. If access to a roof or other elevated area is required, you must provide a means to safely access the area (ladder or manlift as appropriate). Additionally, please secure any animals.

RESPONDENT: 1. Enclosed is a copy of the complaint. Under A.R.S. § 32-1155(D) you must be allowed, upon request, the opportunity to inspect the work complained of within fifteen days of the date of receipt of this notice. 2. To assist the assigned investigator in evaluating the merits of the complaint, please submit a response to the enclosed complaint to the assigned investigator prior to the scheduled inspection. 3. If you do not attend the jobsite inspection, your absence may negatively impact the investigation, and your interests. 4. If a building permit(s) was required for this project, please have the building permit information available at the jobsite inspection.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 If either party needs to reschedule the jobsite inspection, please notify the assigned investigator at least three business days prior to the inspection date to schedule a new date and time.

If the parties resolve the complaint prior to the inspection, please notify the assigned investigator in writing and by phone as soon as possible.

Sincerely, Patricia Schuette Patricia Schuette, Investigator 602 7716744 [email redacted] 1700 W Washington St, Ste 105 Phoenix, AZ 85007

CC: Respondent Complainant

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 A Guide to Jobsite Inspections

Purpose of the Jobsite Inspection When the Registrar receives a complaint against a contractor’s license alleging poor workmanship, the Registrar generally schedules a Jobsite Inspection. The Jobsite Inspection serves two purposes: 1. To give the contractor an opportunity to inspect the complaint items; and 2. To give the Registrar an opportunity to determine if the contractor’s work violates Arizona law.

Jobsite Inspection Rights and Responsibilities Access to inspect: The property owner has complete control over who they allow on the property. However, if the Registrar’s investigator or the contractor cannot inspect the work, the Registrar will not move forward with a citation.

Cooperation: Arizona law enables injured parties to seek relief for damages through several paths. When dealing with a licensed contractor, the Registrar of Contractors’ administrative complaint process may serve as one of those possible paths. However, in order to use that path, the Registrar relies on the cooperation of all parties to a complaint.

Minimum workmanship: The Registrar investigates workmanship complaints for compliance with minimum workmanship and professional industry standards. The Registrar does not issue citations for work that meets these standards.

Scope: The scope of the Jobsite Inspection is limited to items listed in the complaint filed with the Registrar’s office. It is the complainant’s responsibility to point out the complaint item(s) and the Investigators role to review the item(s). If the complainant identifies additional workmanship items not listed in the original complaint, they must file an addendum to the complaint. The Registrar’s Investigator may identify additional administrative violations by the contractor (e.g. work performed out of scope of the license and failure to provide a contract that meets requirements set by Arizona law) at the time of the inspection.

The Role of the Investigator At the Jobsite Inspection, the Registrar’s investigator will: ● Only investigate the items listed on the complaint form filed with the Registrar. ● Will gather evidence to make an informed decision about the complaint items.

What to expect after a Jobsite Inspection After doing a Jobsite Inspection, the Registrar’s Investigator will leave the jobsite and review the evidence provided during the inspection. Generally, the investigator does not make any determination at the time of the jobsite inspection regarding whether the allegations listed in the complaint are supported. ● If the allegations are confirmed, the Registrar’s Investigator may issue a Written Directive telling the contractor to correct the poor or incomplete work. ● If the allegations are not confirmed, the Registrar’s Investigator will close the complaint.

Questions? If you have already filed a complaint and it was assigned to an investigator, you are encouraged to contact that investigator directly with the information listed in your jobsite inspection letter.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 If you have not filed a complaint yet or have not been assigned an investigator, you can reach the Registrar’s compliance department at (877) 692-9762.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 A Guide to Written Directives Purpose of the Jobsite Inspection When the Registrar receives a complaint against a contractor’s license, the Registrar generally schedules a Jobsite Inspection. The Jobsite Inspection serves two purposes: 1. To give the contractor an opportunity to inspect the complaint items; and 2. To give the Registrar an opportunity to determine if the contractor’s work violates Arizona law.

What to expect after a Jobsite Inspection After doing a Jobsite Inspection, the Registrar’s Investigator will determine whether the allegations listed in the complaint are supported. ● If the allegations are confirmed, the Registrar’s Investigator may issue a Written Directive telling the contractor to correct the poor or incomplete work. ● If the allegations are not confirmed, the Registrar’s Investigator will close the complaint.

Written Directives Access: In order to use the administrative process offered by the Registrar, a property owner must provide reasonable access to allow the contractor to fix their work as directed by the Registrar in a Written Directive. Complainants may not put any additional, unnecessary restrictions on the Respondent above and beyond the initial contract requirements agreed upon at the beginning of the project. Respondents are required to make repairs on items identified on any Written Directive, not otherwise restricted by local code or HOA limitations. Complainants must make access available to the Respondent to make the required repairs and failure to provide reasonable access may result in the Registrar dismissing the complaint.

Contractor obligations: The Written Directive will set a deadline for compliance. This is the period of time determined by the Investigator as necessary to complete the items listed in the Directive. ● The deadline for compliance assumes the contractor will promptly begin working on the items listed in the Directive. ● Do not wait. Both parties should communicate quickly to schedule the work.

Extensions: If good cause exists to extend this deadline, either party may submit a written request to the Investigator. The Registrar will review requests for extension and determine if the Directive should be extended.

Manner and method of performance: The Registrar does not provide specific instructions for how to correct poor work. A licensed contractor is expected to have the skill and professionalism to complete the work. Moreover, the complainant may not dictate the manner of repair. If the contractor fails to appropriately correct the work according to the contract, the Registrar will issue a citation.

Compliance Inspection: After the Written Directive expires, the Registrar’s Investigator will contact the complainant to determine if the contractor performed any corrective work. ● If the contractor did corrective work, the Investigator may schedule a Compliance Inspection to determine if the poor work is corrected. ● If the contractor did not perform any corrective work, the Registrar’s Investigator will not do a Compliance Inspection and will determine whether to issue a citation based on the administrative record.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 Work performed after the directive ends: After the Directive period ends, a property owner may choose to allow the contractor to continue its work. The Registrar encourages parties to work cooperatively, but cannot require a homeowner to continue to allow a contractor access to the property after the Directive period ends in order for the administrative process to continue. Denying access after the Directive ends is not grounds to close or dismiss a complaint.

Questions? If you have already filed a complaint and it was assigned to an investigator, you are encouraged to contact that investigator directly with the information listed in your jobsite inspection letter. If you have not filed a complaint yet or have not been assigned an investigator, you can reach the Registrar’s compliance department at (877) 692-9762.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C008 05/21 Jobsite Inspection Notes

Case No.: 2023-10983 Investigator: Patricia Schuette Inspection Date: October 16, 2023 Inspection Time: 10:00 AM

Complainant: Michael Gulas Respondent: R & D Appel LLC Not Present: Not Present:

Jobsite General Notes: Both parties were present including Randy Appel with R & D Appell LLC. I explained process moving forward. IF a violation was determined a written directive would be issued giving minimum of 15 days for correction. The ROC does not dictate how corrections occur other than it must be done in a workmanship like manner and brought up to minimum workmanship standards.

Complaint Item: 1-Downstairs Bath GFCI not working correctly after repeated attempts to fix. Investigator’s Observation: Unverified. It appears that each bathroom was separated from each other and now has their own GFCI in each bath. Governing Rule: N/A

Complaint Item: 2-Downstairs Bath Cabinet drawer is crooked after install. Investigator’s Observation: Verified. The drawer is not sitting square and is crooked. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

Complaint Item: 3-Downstairs Bath P-trap not installed under sink as requested. Investigator’s Observation: Verified. The sink does not have a p- trap as required per plumbing code 1002.1 Fixture traps. Respondent to bring up to code requirements. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 4-Downstairs Bath glue from previous incorrect cabinet install still visible. Investigator’s Observation: Verified. There is some remnants of previous caulking. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 5-Dowstairs Bath shiplap wall not installed per contract. Investigator’s Observation: Verified. The shiplap was not able to be installed due to spacing issues between the back of the toilet and the shiplap itself. Per Respondent a credit for the cost to be applied to the overall total. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 6-Downstairs Bath sink installed on counter incorrect. Gap behind not sealed. Investigator’s Observation: Verified. There is a small space on the backside of the top mounted sink bowl and the countertop that is not sealed. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

work not performed in accordance with professional industry standards.

Complaint Item: 7-Downstairs Bath grout on floor not corrected. Holes still present. Investigator’s Observation: Verified. There were a few places where the floor grout had some voids and not up to the finish edge of the tile. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 8-Downstairs Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a small section behind the sink bowl where the backsplash is not caulked/sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 9-Downstairs Bath base trim replaced but not finished. Investigator’s Observation: Unverified. The contract was for the Complainant to provide painting. Governing Rule: N/A

Complaint Item: 10-Hall Bath sink faucet scratched at install not replaced. Investigator’s Observation: Verified. Respondent stated that a credit would be applied to total bill for the damage. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

work not performed in accordance with professional industry standards.

Complaint Item: 11-Hall Bath outlets replaced multiple times, still not in correct place. Investigator’s Observation: Unverified. There is not enough evidence to support a ruling against the license. The contract does not specify locations of the moved electrical work. Governing Rule: N/A

Complaint Item: 12-Hall Bath GFCI not connected after multiple attempts to fix. Investigator’s Observation: Verified. It appears that each bathroom was separated to have its own GFCI however; the second outlet does not trip power when the GFCI is tripped in the Hall bath. Respondent to identify cause and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 13-Hall Bath attempt to fix tile in shower, used silicone not grout provided. Investigator’s Observation: Unverified. It appears that the material around the tiles replaced is grout. Governing Rule: N/A

Complaint Item: 14-Hall Bath metal plumbing provided not used under sink not corrected. Investigator’s Observation: Verified. Braided supply line was only installed on one side not the other. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

work not performed in accordance with professional industry standards.

Complaint Item: 15-Hall Bath sealing around small window still not completed. Investigator’s Observation: Verified. There is inconsistent grout between tile and window frame on the window above the tub. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 16-Hall Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a gap between the countertop and backsplash. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 17-Hall Bath cabinets have damage and functional issues not corrected. Investigator’s Observation: Verified. There were a few dings/gouges on the face of the doors/drawers. There is also a vanity door that rubbed the drawer fronts when opened. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 18-Hall Bath medicine cabinet replaced and damage to hallway not painted. 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

Investigator’s Observation: Verified. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 19-Hall Bath access cap installed in hallway not necessary per inspection. Investigator’s Observation: Unverified. All electrical junctions must be accessible per code. 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible. Boxes, conduit bodies, and handhole enclosures shall be installed so that the wiring contained in them can be rendered accessible without removing any part of the building or structure or, in underground circuits, without excavating sidewalks, paving, earth, or other substance that is to be used to establish the finished grade. Governing Rule: N/A

Complaint Item: 20-Hall Bath toilet crooked and not corrected. Investigator’s Observation: Verified. The toilet bowl/base is not installed perpendicular or straight with the wall. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 21-Master Bath tub filler damaged and not replaced. Investigator’s Observation: Verified. There is damage/scratch on the fixture. Respondent mentioned applying a credit to total invoice. Correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

work not performed in accordance with professional industry standards.

Complaint Item: 22-Master Bath tile around windows and niche damaged and not replaced. Investigator’s Observation: Verified. There are cut tiles with jagged edges. Respondent to identify all tiles and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 23-Master Bath small window installed twice and crooked per inspection. Investigator’s Observation: Verified. It is uncertain if the window is not installed square or if the tile return to window is not level. Respondent to determine causation and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 24-Master Bath hanging above tub damage and not replaced. Investigator’s Observation: Verified. One of the sconces on the light fixture is cracked. Respondent to correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 25-Master Bath ledge in shower is poorly done and needs to be retiled. Investigator’s Observation: Partially verified. The nature of the tile 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

causes some challenges with grout joint inconsistencies with curved areas however; there are a few places where the tile is chipped. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 26-Master Bath proper sealing in shower not complete per inspection. Investigator’s Observation: Verified. The sealing or waterproofing is behind the tile and not able to view however, the complaint was really about the horizontal to vertical transitions and where the shower floor tile meets the wall tile that is cracked. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 27-Master Bath cabinets installed incorrectly wall tile and floor not replaced. Investigator’s Observation: Verified. There is a miss measure either from the vanity, countertop, or shower dimension causing an alignment problem with the overlap of the shower wall tile over the countertop, shortened backsplash on the top and a slight overhang of vanity over the shower curb. Respondent to determine causation and correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 28-Master Bath cabinets have functional issues and damage not corrected. Investigator’s Observation: Verified. There are some gouges/chips 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

and drawers/doors that do not operate full swing or pull. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 29-Master Bath sealing on countertops not completed. Investigator’s Observation: Verified. The top to backsplash is not fully caulked or sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 30-Master bath several areas of floor grout defects have not been fixed. Investigator’s Observation: Verified. There are several locations where there is pinholes or low spots in the floor grout. Respondent to identify locations and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 31-Master Bath floor tile around toilet damaged and not replaced. Investigator’s Observation: Verified. There is caulking that is on grout where the toilet used to sit. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

Complaint Item: 32-Master Bath shower handles installed crooked not fixed per inspection. Investigator’s Observation: Unverified. The position of the base of the handles is determined by the location of the stud that they are attached to. The resting location of the handle themselves do not align when in the off position but not a workmanship issue. Governing Rule: N/A

Complaint Item: 33-Master Bath bedroom ceiling paint damaged not repaired or repainted. Investigator’s Observation: Verified. There are a few spots where containment was secured to wall/ceiling and damaged paint when removed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov RCC100 08/19

Complainant: Michael Gulas 19352 E Thornton Rd Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Respondent: R & D Appel LLC DBA: The Edge Remodeling 21620 E Nightingale Dr Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 November 1, 2023

License No. ROC 237727

Re:Complaint No. 2023-10983

WRITTEN DIRECTIVE FROM THE REGISTRAR

Dear Respondent:

After investigation, the Registrar determined that you failed to meet the requirements of A.R.S. § 32-1154(A), and now issues this Directive requiring you to take appropriate corrective action. Failure to comply with this Directive constitutes a violation of A.R.S. § 32-1154(A)(22) and may result in the issuance of a citation, discipline of your license, and a civil penalty pursuant to A.R.S. § 32-1154(E) of up to $500.00. You must notify the Registrar’s assigned Investigator of your compliance with this Directive prior to 5:00 p.m. on November 21, 2023.

RESTRICTIONS  You may not perform or hire other contractors to perform work that is outside the scope of your license.  If your license is currently suspended for administrative reasons1, or is inactive, expired, or cancelled, you may not perform any corrective work nor contract in any manner, which includes hiring other contractors to perform work, until the suspension of your license(s) has been lifted or your license(s) has been reactivated.

DIRECTIVE REQUIREMENTS You are directed to remedy the following violations by the appropriate means:

Complaint Item: 2-Downstairs Bath Cabinet drawer is crooked after install. Investigator’s Observation: Verified. The drawer is not sitting square and is crooked. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

This means the license is suspended for lack of qualifying party, lack of bond, nonrenewal, Recovery Fund payout, or for any reason listed in A.R.S. § 32-1124(F). 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 3-Downstairs Bath P-trap not installed under sink as requested. Investigator’s Observation: Verified. The sink does not have a p-trap as required per plumbing code 1002.1 Fixture traps. Respondent to bring up to code requirements. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 4-Downstairs Bath glue from previous incorrect cabinet install still visible. Investigator’s Observation: Verified. There is some remnants of previous caulking. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 5-Dowstairs Bath shiplap wall not installed per contract. Investigator’s Observation: Verified. The shiplap was not able to be installed due to spacing issues between the back of the toilet and the shiplap itself. Per Respondent a credit for the cost to be applied to the overall total. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 6-Downstairs Bath sink installed on counter incorrect. Gap behind not sealed. Investigator’s Observation: Verified. There is a small space on the backside of the top mounted sink bowl and the countertop that is not sealed.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards. Complaint Item: 7-Downstairs Bath grout on floor not corrected. Holes still present. Investigator’s Observation: Verified. There were a few places where the floor grout had some voids and not up to the finish edge of the tile. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 8-Downstairs Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a small section behind the sink bowl where the backsplash is not caulked/sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 10-Hall Bath sink faucet scratched at install not replaced. Investigator’s Observation: Verified. Respondent stated that a credit would be applied to total bill for the damage. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 12-Hall Bath GFCI not connected after multiple attempts to fix. Investigator’s Observation: Verified. It appears that each bathroom was separated to have its own GFCI however; the second outlet does not trip power when the GFCI is tripped in the Hall bath. Respondent to identify cause and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 14-Hall Bath metal plumbing provided not used under sink not corrected. Investigator’s Observation: Verified. Braided supply line was only installed on one side not the other. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 15-Hall Bath sealing around small window still not completed. Investigator’s Observation: Verified. There is inconsistent grout between tile and window frame on the window above the tub. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 16-Hall Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a gap between the

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 countertop and backsplash. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 17-Hall Bath cabinets have damage and functional issues not corrected. Investigator’s Observation: Verified. There were a few dings/gouges on the face of the doors/drawers. There is also a vanity door that rubbed the drawer fronts when opened. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 18-Hall Bath medicine cabinet replaced and damage to hallway not painted. Investigator’s Observation: Verified. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 20-Hall Bath toilet crooked and not corrected. Investigator’s Observation: Verified. The toilet bowl/base is not installed perpendicular or straight with the wall. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 21-Master Bath tub filler damaged and not replaced. Investigator’s Observation: Verified. There is damage/scratch on the fixture. Respondent mentioned applying a credit to total invoice. Correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 22-Master Bath tile around windows and niche damaged and not replaced. Investigator’s Observation: Verified. There are cut tiles with jagged edges. Respondent to identify all tiles and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 23-Master Bath small window installed twice and crooked per inspection. Investigator’s Observation: Verified. It is uncertain if the window is not installed square or if the tile return to window is not level. Respondent to determine causation and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 24-Master Bath hanging above tub damage and not replaced. Investigator’s Observation: Verified. One of the sconces on the light

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 fixture is cracked. Respondent to correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 25-Master Bath ledge in shower is poorly done and needs to be retiled. Investigator’s Observation: Partially verified. The nature of the tile causes some challenges with grout joint inconsistencies with curved areas however; there are a few places where the tile is chipped. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 26-Master Bath proper sealing in shower not complete per inspection. Investigator’s Observation: Verified. The sealing or waterproofing is behind the tile and not able to view however, the complaint was really about the horizontal to vertical transitions and where the shower floor tile meets the wall tile that is cracked. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 27-Master Bath cabinets installed incorrectly wall tile and floor not replaced. Investigator’s Observation: Verified. There is a miss measure either from the vanity, countertop, or shower dimension causing an alignment

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 problem with the overlap of the shower wall tile over the countertop, shortened backsplash on the top and a slight overhang of vanity over the shower curb. Respondent to determine causation and correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 28-Master Bath cabinets have functional issues and damage not corrected. Investigator’s Observation: Verified. There are some gouges/chips and drawers/doors that do not operate full swing or pull. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 29-Master Bath sealing on countertops not completed. Investigator’s Observation: Verified. The top to backsplash is not fully caulked or sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 30-Master bath several areas of floor grout defects have not been fixed. Investigator’s Observation: Verified. There are several locations where there is pinholes or low spots in the floor grout. Respondent to identify locations and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 work not performed in accordance with professional industry standards.

Complaint Item: 31-Master Bath floor tile around toilet damaged and not replaced. Investigator’s Observation: Verified. There is caulking that is on grout where the toilet used to sit. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 33-Master Bath bedroom ceiling paint damaged not repaired or repainted. Investigator’s Observation: Verified. There are a few spots where containment was secured to wall/ceiling and damaged paint when removed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

ITEMS NOT REQUIRING CORRECTION The following complaint items require no action by the Respondent:

Complaint Item: 1-Downstairs Bath GFCI not working correctly after repeated attempts to fix. Investigator’s Observation: Unverified. It appears that each bathroom was separated from each other and now has their own GFCI in each bath. Governing Rule: N/A

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 9-Downstairs Bath base trim replaced but not finished. Investigator’s Observation: Unverified. The contract was for the Complainant to provide painting. Governing Rule: N/A

Complaint Item: 11-Hall Bath outlets replaced multiple times, still not in correct place. Investigator’s Observation: Unverified. There is not enough evidence to support a ruling against the license. The contract does not specify locations of the moved electrical work. Governing Rule: N/A

Complaint Item: 13-Hall Bath attempt to fix tile in shower, used silicone not grout provided. Investigator’s Observation: Unverified. It appears that the material around the tiles replaced is grout. Governing Rule: N/A

Complaint Item: 19-Hall Bath access cap installed in hallway not necessary per inspection. Investigator’s Observation: Unverified. All electrical junctions must be accessible per code. 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible. Boxes, conduit bodies, and handhole enclosures shall be installed so that the wiring contained in them can be rendered accessible without removing any part of the building or structure or, in underground circuits, without excavating sidewalks, paving, earth, or other substance that is to be used to establish the finished grade. Governing Rule: N/A

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 32-Master Bath shower handles installed crooked not fixed per inspection. Investigator’s Observation: Unverified. The position of the base of the handles is determined by the location of the stud that they are attached to. The resting location of the handle themselves do not align when in the off position but not a workmanship issue. Governing Rule: N/A

Please direct all questions regarding this Directive to the undersigned Investigator.

Sincerely,

Patricia Schuette Patricia Schuette, Investigator 602 7716744 [email redacted] 1700 W Washington St, Ste 105 Phoenix, AZ 85007

CC: Respondent Complainant

License mailing address (if different from account/company address of record):

R & D Appel LLC The Edge Remodeling 22246 S Ellsworth Rd Queen Creek, AZ 85142-8358

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complainant: Michael Gulas 19352 E Thornton Rd Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Respondent: R & D Appel LLC DBA: The Edge Remodeling 21620 E Nightingale Dr Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 December 22, 2023

License No. ROC 237727

Re:Complaint No. 2023-10983

AMENDED WRITTEN DIRECTIVE FROM THE REGISTRAR

Dear Respondent:

After investigation, the Registrar determined that you failed to meet the requirements of A.R.S. § 32-1154(A), and now issues this Directive requiring you to take appropriate corrective action. Failure to comply with this Directive constitutes a violation of A.R.S. § 32-1154(A)(22) and may result in the issuance of a citation, discipline of your license, and a civil penalty pursuant to A.R.S. § 32-1154(E) of up to $500.00. You must notify the Registrar’s assigned Investigator of your compliance with this Directive prior to 5:00 p.m. on January 5, 2024.

RESTRICTIONS  You may not perform or hire other contractors to perform work that is outside the scope of your license.  If your license is currently suspended for administrative reasons1, or is inactive, expired, or cancelled, you may not perform any corrective work nor contract in any manner, which includes hiring other contractors to perform work, until the suspension of your license(s) has been lifted or your license(s) has been reactivated.

DIRECTIVE REQUIREMENTS You are directed to remedy the following violations by the appropriate means:

Complaint Item: 2-Downstairs Bath Cabinet drawer is crooked after install. Investigator’s Observation: Verified. The drawer is not sitting square and is crooked. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

This means the license is suspended for lack of qualifying party, lack of bond, nonrenewal, Recovery Fund payout, or for any reason listed in A.R.S. § 32-1124(F). 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 3-Downstairs Bath P-trap not installed under sink as requested. Investigator’s Observation: Verified. The sink does not have a p-trap as required per plumbing code 1002.1 Fixture traps. Respondent to bring up to code requirements. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 4-Downstairs Bath glue from previous incorrect cabinet install still visible. Investigator’s Observation: Verified. There is some remnants of previous caulking. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 5-Dowstairs Bath shiplap wall not installed per contract. Investigator’s Observation: Verified. The shiplap was not able to be installed due to spacing issues between the back of the toilet and the shiplap itself. Per Respondent a credit for the cost to be applied to the overall total. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 6-Downstairs Bath sink installed on counter incorrect. Gap behind not sealed. Investigator’s Observation: Verified. There is a small space on the backside of the top mounted sink bowl and the countertop that is not sealed.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards. Complaint Item: 7-Downstairs Bath grout on floor not corrected. Holes still present. Investigator’s Observation: Verified. There were a few places where the floor grout had some voids and not up to the finish edge of the tile. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 8-Downstairs Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a small section behind the sink bowl where the backsplash is not caulked/sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 10-Hall Bath sink faucet scratched at install not replaced. Investigator’s Observation: Verified. Respondent stated that a credit would be applied to total bill for the damage. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 12-Hall Bath GFCI not connected after multiple attempts to fix. Investigator’s Observation: Verified. It appears that each bathroom was separated to have its own GFCI however; the second outlet does not trip power when the GFCI is tripped in the Hall bath. Respondent to identify cause and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 14-Hall Bath metal plumbing provided not used under sink not corrected. Investigator’s Observation: Verified. Braided supply line was only installed on one side not the other. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 15-Hall Bath sealing around small window still not completed. Investigator’s Observation: Verified. There is inconsistent grout between tile and window frame on the window above the tub. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 16-Hall Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a gap between the

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 countertop and backsplash. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 17-Hall Bath cabinets have damage and functional issues not corrected. Investigator’s Observation: Verified. There were a few dings/gouges on the face of the doors/drawers. There is also a vanity door that rubbed the drawer fronts when opened. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 18-Hall Bath medicine cabinet replaced and damage to hallway not painted. Investigator’s Observation: Verified. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 20-Hall Bath toilet crooked and not corrected. Investigator’s Observation: Verified. The toilet bowl/base is not installed perpendicular or straight with the wall. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 21-Master Bath tub filler damaged and not replaced. Investigator’s Observation: Verified. There is damage/scratch on the fixture. Respondent mentioned applying a credit to total invoice. Correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 22-Master Bath tile around windows and niche damaged and not replaced. Investigator’s Observation: Verified. There are cut tiles with jagged edges. Respondent to identify all tiles and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 23-Master Bath small window installed twice and crooked per inspection. Investigator’s Observation: Verified. It is uncertain if the window is not installed square or if the tile return to window is not level. Respondent to determine causation and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 24-Master Bath hanging above tub damage and not replaced. Investigator’s Observation: Verified. One of the sconces on the light

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 fixture is cracked. Respondent to correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 25-Master Bath ledge in shower is poorly done and needs to be retiled. Investigator’s Observation: Partially verified. The nature of the tile causes some challenges with grout joint inconsistencies with curved areas however; there are a few places where the tile is chipped. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 26-Master Bath proper sealing in shower not complete per inspection. Investigator’s Observation: Verified. The sealing or waterproofing is behind the tile and not able to view however, the complaint was really about the horizontal to vertical transitions and where the shower floor tile meets the wall tile that is cracked. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 27-Master Bath cabinets installed incorrectly wall tile and floor not replaced. Investigator’s Observation: Verified. There is a miss measure either from the vanity, countertop, or shower dimension causing an alignment

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 problem with the overlap of the shower wall tile over the countertop, shortened backsplash on the top and a slight overhang of vanity over the shower curb. Respondent to determine causation and correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 28-Master Bath cabinets have functional issues and damage not corrected. Investigator’s Observation: Verified. There are some gouges/chips and drawers/doors that do not operate full swing or pull. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 29-Master Bath sealing on countertops not completed. Investigator’s Observation: Verified. The top to backsplash is not fully caulked or sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 30-Master bath several areas of floor grout defects have not been fixed. Investigator’s Observation: Verified. There are several locations where there is pinholes or low spots in the floor grout. Respondent to identify locations and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 work not performed in accordance with professional industry standards.

Complaint Item: 31-Master Bath floor tile around toilet damaged and not replaced. Investigator’s Observation: Verified. There is caulking that is on grout where the toilet used to sit. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Complaint Item: 33-Master Bath bedroom ceiling paint damaged not repaired or repainted. Investigator’s Observation: Verified. There are a few spots where containment was secured to wall/ceiling and damaged paint when removed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

ITEMS NOT REQUIRING CORRECTION The following complaint items require no action by the Respondent:

Complaint Item: 1-Downstairs Bath GFCI not working correctly after repeated attempts to fix. Investigator’s Observation: Unverified. It appears that each bathroom was separated from each other and now has their own GFCI in each bath. Governing Rule: N/A

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 9-Downstairs Bath base trim replaced but not finished. Investigator’s Observation: Unverified. The contract was for the Complainant to provide painting. Governing Rule: N/A

Complaint Item: 11-Hall Bath outlets replaced multiple times, still not in correct place. Investigator’s Observation: Unverified. There is not enough evidence to support a ruling against the license. The contract does not specify locations of the moved electrical work. Governing Rule: N/A

Complaint Item: 13-Hall Bath attempt to fix tile in shower, used silicone not grout provided. Investigator’s Observation: Unverified. It appears that the material around the tiles replaced is grout. Governing Rule: N/A

Complaint Item: 19-Hall Bath access cap installed in hallway not necessary per inspection. Investigator’s Observation: Unverified. All electrical junctions must be accessible per code. 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible. Boxes, conduit bodies, and handhole enclosures shall be installed so that the wiring contained in them can be rendered accessible without removing any part of the building or structure or, in underground circuits, without excavating sidewalks, paving, earth, or other substance that is to be used to establish the finished grade. Governing Rule: N/A

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complaint Item: 32-Master Bath shower handles installed crooked not fixed per inspection. Investigator’s Observation: Unverified. The position of the base of the handles is determined by the location of the stud that they are attached to. The resting location of the handle themselves do not align when in the off position but not a workmanship issue. Governing Rule: N/A

Please direct all questions regarding this Directive to the undersigned Investigator.

Sincerely,

Patricia Schuette Patricia Schuette, Investigator 602 7716744 [email redacted] 1700 W Washington St, Ste 105 Phoenix, AZ 85007

CC: Respondent Complainant

License mailing address (if different from account/company address of record):

R & D Appel LLC The Edge Remodeling 22246 S Ellsworth Rd Queen Creek, AZ 85142-8358

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Complainant: Michael Gulas 19352 E Thornton Rd Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Respondent: R & D Appel LLC DBA: The Edge Remodeling 21620 E Nightingale Dr Queen Creek, AZ 85142

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 January 10, 2024

License No. ROC 237727

Re:Complaint No. 2023-10983

AMENDED WRITTEN DIRECTIVE FROM THE REGISTRAR

Dear Respondent:

After investigation, the Registrar determined that you failed to meet the requirements of A.R.S. § 32-1154(A), and now issues this Directive requiring you to take appropriate corrective action. Failure to comply with this Directive constitutes a violation of A.R.S. § 32-1154(A)(22) and may result in the issuance of a citation, discipline of your license, and a civil penalty pursuant to A.R.S. § 32-1154(E) of up to $500.00. You must notify the Registrar’s assigned Investigator of your compliance with this Directive prior to 5:00 p.m. on January 22, 2024.

RESTRICTIONS  You may not perform or hire other contractors to perform work that is outside the scope of your license.  If your license is currently suspended for administrative reasons1, or is inactive, expired, or cancelled, you may not perform any corrective work nor contract in any manner, which includes hiring other contractors to perform work, until the suspension of your license(s) has been lifted or your license(s) has been reactivated.

DIRECTIVE REQUIREMENTS You are directed to remedy the following violations by the appropriate means:

Compliance Item: 2-Downstairs Bath Cabinet drawer is crooked after install. Investigator’s Observation: Verified. The drawer is not sitting square and is crooked. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

This means the license is suspended for lack of qualifying party, lack of bond, nonrenewal, Recovery Fund payout, or for any reason listed in A.R.S. § 32-1124(F). 1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Compliance Item: 3-Downstairs Bath P-trap not installed under sink as requested. Investigator’s Observation: Verified. The sink does not have a p-trap as required per plumbing code 1002.1 Fixture traps. Respondent to bring up to code requirements. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 4-Downstairs Bath glue from previous incorrect cabinet install still visible. Investigator’s Observation: Verified. There is some remnants of previous caulking. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 5-Dowstairs Bath shiplap wall not installed per contract. Investigator’s Observation: Verified. The shiplap was not able to be installed due to spacing issues between the back of the toilet and the shiplap itself. Per Respondent a credit for the cost to be applied to the overall total. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 6-Downstairs Bath sink installed on counter incorrect. Gap behind not sealed. Investigator’s Observation: Verified. There is a small space on the

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 backside of the top mounted sink bowl and the countertop that is not sealed. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards. Compliance Item: 7-Downstairs Bath grout on floor not corrected. Holes still present. Investigator’s Observation: Verified. There were a few places where the floor grout had some voids and not up to the finish edge of the tile. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 8-Downstairs Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a small section behind the sink bowl where the backsplash is not caulked/sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 10-Hall Bath sink faucet scratched at install not replaced. Investigator’s Observation: Verified. Respondent stated that a credit would be applied to total bill for the damage. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 work not performed in accordance with professional industry standards.

Compliance Item: 12-Hall Bath GFCI not connected after multiple attempts to fix. Investigator’s Observation: Verified. It appears that each bathroom was separated to have its own GFCI however; the second outlet does not trip power when the GFCI is tripped in the Hall bath. Respondent to identify cause and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 14-Hall Bath metal plumbing provided not used under sink not corrected. Investigator’s Observation: Verified. Braided supply line was only installed on one side not the other. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 15-Hall Bath sealing around small window still not completed. Investigator’s Observation: Verified. There is inconsistent grout between tile and window frame on the window above the tub. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Compliance Item: 16-Hall Bath sealing around countertops not completed. Investigator’s Observation: Verified. There is a gap between the countertop and backsplash. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 17-Hall Bath cabinets have damage and functional issues not corrected. Investigator’s Observation: Verified. There were a few dings/gouges on the face of the doors/drawers. There is also a vanity door that rubbed the drawer fronts when opened. Respondent to identify areas and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 18-Hall Bath medicine cabinet replaced and damage to hallway not painted. Investigator’s Observation: Verified. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 20-Hall Bath toilet crooked and not corrected. Investigator’s Observation: Verified. The toilet bowl/base is not installed perpendicular or straight with the wall. Repair within appropriate means.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 21-Master Bath tub filler damaged and not replaced. Investigator’s Observation: Verified. There is damage/scratch on the fixture. Respondent mentioned applying a credit to total invoice. Correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 22-Master Bath tile around windows and niche damaged and not replaced. Investigator’s Observation: Verified. There are cut tiles with jagged edges. Respondent to identify all tiles and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 23-Master Bath small window installed twice and crooked per inspection. Investigator’s Observation: Verified. It is uncertain if the window is not installed square or if the tile return to window is not level. Respondent to determine causation and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Compliance Item: 24-Master Bath hanging above tub damage and not replaced. Investigator’s Observation: Verified. One of the sconces on the light fixture is cracked. Respondent to correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 25-Master Bath ledge in shower is poorly done and needs to be retiled. Investigator’s Observation: Partially verified. The nature of the tile causes some challenges with grout joint inconsistencies with curved areas however; there are a few places where the tile is chipped. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 26-Master Bath proper sealing in shower not complete per inspection. Investigator’s Observation: Verified. The sealing or waterproofing is behind the tile and not able to view however, the complaint was really about the horizontal to vertical transitions and where the shower floor tile meets the wall tile that is cracked. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Compliance Item: 27-Master Bath cabinets installed incorrectly wall tile and floor not replaced. Investigator’s Observation: Verified. There is a miss measure either from the vanity, countertop, or shower dimension causing an alignment problem with the overlap of the shower wall tile over the countertop, shortened backsplash on the top and a slight overhang of vanity over the shower curb. Respondent to determine causation and correct within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 28-Master Bath cabinets have functional issues and damage not corrected. Investigator’s Observation: Verified. There are some gouges/chips and drawers/doors that do not operate full swing or pull. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 29-Master Bath sealing on countertops not completed. Investigator’s Observation: Verified. The top to backsplash is not fully caulked or sealed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 30-Master bath several areas of floor grout defects have not been fixed.

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Investigator’s Observation: Verified. There are several locations where there is pinholes or low spots in the floor grout. Respondent to identify locations and repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 31-Master Bath floor tile around toilet damaged and not replaced. Investigator’s Observation: Verified. There is caulking that is on grout where the toilet used to sit. Respondent to repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

Compliance Item: 33-Master Bath bedroom ceiling paint damaged not repaired or repainted. Investigator’s Observation: Verified. There are a few spots where containment was secured to wall/ceiling and damaged paint when removed. Repair within appropriate means. Governing Rule: ARS §32-1154 (A) (3) namely R4-9-108, Poor work not performed in accordance with professional industry standards.

ITEMS NOT REQUIRING CORRECTION The following complaint items require no action by the Respondent:

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Compliance Item: 1-Downstairs Bath GFCI not working correctly after repeated attempts to fix. Investigator’s Observation: Unverified. It appears that each bathroom was separated from each other and now has their own GFCI in each bath. Governing Rule: N/A

Compliance Item: 9-Downstairs Bath base trim replaced but not finished. Investigator’s Observation: Unverified. The contract was for the Complainant to provide painting. Governing Rule: N/A

Compliance Item: 11-Hall Bath outlets replaced multiple times, still not in correct place. Investigator’s Observation: Unverified. There is not enough evidence to support a ruling against the license. The contract does not specify locations of the moved electrical work. Governing Rule: N/A

Compliance Item: 13-Hall Bath attempt to fix tile in shower, used silicone not grout provided. Investigator’s Observation: Unverified. It appears that the material around the tiles replaced is grout. Governing Rule: N/A

Compliance Item: 19-Hall Bath access cap installed in hallway not necessary per inspection. Investigator’s Observation: Unverified. All electrical junctions must be accessible per code. 314.29 Boxes, Conduit Bodies, and Handhole Enclosures to Be Accessible. Boxes, conduit bodies, and handhole

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 enclosures shall be installed so that the wiring contained in them can be rendered accessible without removing any part of the building or structure or, in underground circuits, without excavating sidewalks, paving, earth, or other substance that is to be used to establish the finished grade. Governing Rule: N/A

Compliance Item: 32-Master Bath shower handles installed crooked not fixed per inspection. Investigator’s Observation: Unverified. The position of the base of the handles is determined by the location of the stud that they are attached to. The resting location of the handle themselves do not align when in the off position but not a workmanship issue. Governing Rule: N/A

Please direct all questions regarding this Directive to the undersigned Investigator.

Sincerely,

Patricia Schuette Patricia Schuette, Investigator 602 7716744 [email redacted] 1700 W Washington St, Ste 105 Phoenix, AZ 85007

CC: Respondent Complainant

License mailing address (if different from account/company address of record):

R & D Appel LLC The Edge Remodeling 22246 S Ellsworth Rd

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 Queen Creek, AZ 85142-8358

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812

602.542.1525 · Toll Free 877.692.9762 · roc.az.gov C009 04/21 REGISTRAR OF CONTRACTORS OF THE STATE OF ARIZONA

Michael Gulas, Case No. 2023-10983

COMPLAINANT, v. CITATION R & D Appel LLC, DBA: The Edge Remodeling, License No. ROC 237727, 349555 RESPONDENT.

The Registrar issues this Citation to R & D Appel LLC, DBA: The Edge Remodeling (“Respondent”) under A.R.S. § 32-1155(A). If Respondent fails to answer this Citation by February 16, 2024, then under A.R.S. § 32-1155(C), Respondent’s failure to answer may be deemed an admission of the act or acts charged in the underlying complaint, and the Registrar may then suspend or revoke Respondent’s license(s). THE WRITTEN COMPLAINT On September 20, 2023, Michael Gulas, (“Complainant”) filed a written complaint with the Registrar. A copy of that Complaint is attached to this Citation. A FORMAL STATEMENT OF THE CHARGES AGAINST RESPONDENT The Registrar investigated this matter and finds cause to charge Respondent with violation(s) of Title 32, Chapter 10 of the Arizona Revised Statutes. Respondent is charged with violating: Charge :1 A.R.S. § 32-1154(A)(3) - R4-9-108(a) Violation of any rule adopted by the Registrar; Namely A.A.C. R4-9-108(a): A contractor shall perform all work in a professional and workmanlike manner. of 6

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Toll Free 877.692.9762 · roc.az.gov Lg101 8/21 Charge :2 A.R.S. § 32-1154(A)(22) Failure to take appropriate corrective action to comply with this chapter or with rules adopted pursuant to this chapter without valid justification within a reasonable period of time after receiving a written directive from the Registrar. The written directive shall set forth the time within which the contractor is to complete the remedial action. The time permitted for compliance shall not be less than fifteen days from the date of issuance of the directive. A license shall not be revoked or suspended nor shall any other penalty be imposed for a violation of this paragraph until after a hearing has been held. If the matter proceeds to a hearing and the administrative law judge determines that any of the charges listed above are supported by a preponderance of the evidence, then Respondent’s license(s) may be subject to suspension or revocation, and Respondent may be subject to other penalties provided by law, including civil penalties under A.R.S. §§ 32-1154(E) and (F). FILING A WRITTEN ANSWER Respondent must appear by filing with the Registrar a written answer to the citation and complaint showing cause, if any, why Respondent’s license(s) should not be suspended or revoked. A.R.S. § 32-1155(A). Respondent’s written answer should contain the heading “Written Answer to Citation and Complaint” and should include the case number, which is Case No. 2023-10983. How to File a Written Answer: Respondent’s written answer may be submitted in the following ways: In-Person: 1700 W. Washington St., Ste. 105, Phoenix, Arizona, 85007-2812 Mail: P.O. Box 18244, Phoenix, Arizona, 85005-8244 Email: [email redacted]

of 6

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Toll Free 877.692.9762 · roc.az.gov Lg101 8/21 The Registrar’s normal office hours are 8:00 a.m. to 5:00 p.m., Monday through Friday. If Respondent submits a written answer by mail, it is not filed with the Registrar until the Registrar actually receives it. Deadline for Filing a Written Answer: Respondent must file a written answer with the Registrar no later than February 16, 2024. This deadline is calculated under A.R.S. §§ 32-1155(A) and (B), which provides a deadline ten days after service of the Citation. Service of the Citation and Complaint is complete five days after the Registrar mails a copy of the Citation and Complaint to Respondent’s latest address of record in the Registrar’s office. Consequences for Failing to File a Written Answer: If Respondent fails to answer, Respondent’s failure may be deemed an admission of the act or acts charged in the written complaint. A.R.S. § 32-1155(C). The Registrar may then suspend or revoke Respondent’s license(s). THE ADMINISTRATIVE HEARING If Respondent files a timely written answer contesting any charges in the Complaint, then the Registrar will request the Office of Administrative Hearings set a date for an administrative hearing and will notify all the parties at least 30 days before that hearing. A.R.S. § 41-1092.05(D). INVESTIGATOR’S APPEARANCE AS A WITNESS The Registrar’s assigned investigator will appear as a witness at the hearing. If either party demands the attendance at the hearing of any other person, that party must obtain and serve a subpoena in compliance with the rules and processes established by the Office of Administrative Hearings.

of 6

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Toll Free 877.692.9762 · roc.az.gov Lg101 8/21 RESPONDENT’S RIGHT TO REQUEST AN INFORMAL SETTLEMENT CONFERENCE Under A.R.S. § 41-1092.06, if Respondent submits a request to the Registrar for an informal settlement conference, the Registrar must hold a conference within 15 days after receiving the request. Respondent’s request for an informal settlement conference must be in writing and must be filed no later than 20 days before the administrative hearing. A.R.S. § 41- 1092.06(A). The Registrar will not close or settle any case without both parties’ appearance at the Settlement Conference. The parties participating in the settlement conference must have the authority to settle the case and must waive their right to object to the participation of the Registrar’s settlement conference representative in the final administrative decision. A.R.S. § 41-1092.06(B). Any statements, either written or oral, made by the parties at the conference, including a written document, created or expressed solely for the purpose of settlement negotiations, are inadmissible in the administrative hearing. A.R.S. § 41-1092.06(B).

RESPONDENT’S PRIOR RECORD Under A.A.C. R4-9-117, in determining the appropriate discipline, the administrative law judge and the Registrar may consider not only facts in the current case, but also facts in prior cases and any documents regarding Respondent on file with the Registrar. Respondent’s prior disciplinary record and current license(s) status may be considered as a mitigating or aggravating factor in determining the appropriate discipline. EVIDENTIARY DISCLAIMER By issuing this Citation, the Registrar is directing Respondent to file a written answer to the Citation and Complaint, showing cause, if any, why Respondent’s license(s) should not be suspended or revoked. A.R.S. § 32-1155(A). This Citation does not constitute proof that any

of 6

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Toll Free 877.692.9762 · roc.az.gov Lg101 8/21 charge or allegation in Complainant’s written complaint is in fact true. This Citation does not constitute proof that Respondent violated any statutory provision or rule adopted by the Registrar. Dated February 1, 2024. By: /s/ Gail Mathews Gail Mathews Legal Assistant II Legal Department Arizona Registrar of Contractors

COPY of the foregoing mailed by Certified Mail, Return Receipt Requested, February 1, 2024 to: Respondent Certified Mail No: [number redacted] R & D Appel LLC DBA: The Edge Remodeling 22246 S Ellsworth Rd Queen Creek, AZ 85142-8358 Copy mailed by USPS First Class mail this same date to:

Respondent R & D Appel LLC 21600 S Crismon Rd Queen Creek, AZ 85142

R & D Appel LLC DBA: The Edge Remodeling 22246 S Ellsworth Rd Queen Creek, AZ 85142-8358

Complainant Michael Gulas 19352 E Thornton Rd Queen Creek, AZ 85142

of 6

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Toll Free 877.692.9762 · roc.az.gov Lg101 8/21 Copy sent electronically this same date to: Respondent at email address on record with the Registrar Complainant at email address on record with the Registrar

Case No. 2023-10983

of 6

1700 W. Washington Street, Suite 105 · Phoenix AZ 85007-2812 602.542.1525 · Toll Free 877.692.9762 · roc.az.gov Lg101 8/21 2/15/24, 4:49 PM State of Arizona Mail - FW: Citation and Complaint 2023-10983

Answers - AZROC <[email redacted]>

FW: Citation and Complaint 2023-10983 message

Randy <[email redacted]> Thu, Feb 15, 2024 at 3:43 PM To: "[email redacted]" <[email redacted]>

Gail, We have been trying for a year to get this resolved. The homeowner keeps pushing it off to get done. Personally, I feel he doesn’t have the money to pay final. At this point everything he has left is workmanship stuff. His final balance has been due for a year now with every excuse in the book not to pay. My sub-contractors are done with this guy as well. Even working with the ROC on this. The inspector has extended this 2 times because he will not give us dates to get it done. From December 11th when asked for a date till end of January On the last extension. He waits till the 11th hour and says (Concerning the remaining directives, we are available this week and will await possible days to schedule the completion from Randy and then nothing. I told the inspector I was done with this guy.

Randy Appel

-------- Original message --------

From: Gail Mathews <[email redacted]>

Date: 1/31/24 4:25 PM (GMT-07:00)

To:

Subject: Citation and Complaint 2023-10983

Attached is an electronic courtesy copy of the citation and complaint that was mailed and issued via US mail.

Please do not reply directly to this email. Any reply or response should be addressed to [email redacted]

Sincerely,

--

Gail Mathews

https://mail.google.com/mail/b/AEoRXRQDPHgmC9ojv0oOpx2Cq3QHypyPEgS0XA1lbVWjOBqFZZtD/u/0/?ik=581c53cf5c&view=pt&search=all&per… 1/2 2/15/24, 4:49 PM State of Arizona Mail - FW: Citation and Complaint 2023-10983 Legal Assistant

602-771-6804

[email redacted]

1700 W Washington Suite 105

Phoenix, AZ 85007

Fill out AZ ROC's survey to let us know how we're doing and how we can better serve you!

The ROC is now on social media! Make sure to follow us on:

20240201 Citation & Complaint 2023-10983.pdf 6323K

https://mail.google.com/mail/b/AEoRXRQDPHgmC9ojv0oOpx2Cq3QHypyPEgS0XA1lbVWjOBqFZZtD/u/0/?ik=581c53cf5c&view=pt&search=all&per… 2/2 Complaint #2023-10983 P 1 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 2 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 3 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 4 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 5 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 6 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 7 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 8 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 9 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 10 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 11 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 12 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 13 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 14 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 15 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 16 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 17 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 18 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 19 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 20 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 21 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 22 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 23 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 24 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 25 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 26 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 27 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 28 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 29 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 30 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 31 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 32 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 33 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 34 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 35 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 36 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 37 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 38 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 39 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 40 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 41 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 42 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 43 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 44 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 45 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 46 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 47 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 48 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 49 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 50 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 51 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 52 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 53 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 54 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Complaint #2023-10983 P 55 JSI date 10/16/2023 at 10:00AM JSI PHOTOS Mediation Notice

Mediation Services Mediation services are available to the parties. What is Mediation? Mediation is a method of resolving disputes where the parties can end conflict without the expense and time associated with the full administrative process. Who Participates in During mediation, a mediator will attempt to help the Mediation? parties find an optimal solution to the conflict. Both parties must agree to participate in mediation, and both parties must bring a representative to mediation that has full authority to settle the entire matter. Mediation Is Not Neither the Registrar nor the Office of Administrative Mandatory Hearings will penalize a party for not agreeing to mediation. Where do the Parties The parties will meet at the Office of Administrative Meet for Mediation? Hearings to participate in mediation.

The Office of Administrative Hearings is located at 1400 West Washington, Suite 101, Phoenix, Arizona 85007. When does Mediation can occur after the Registrar issues a citation, but Mediation Occur? before the administrative hearing. Why Should Parties Mediation can be an alternative to the full administrative Consider Mediation? process. Mediation is beneficial because it is (1) time- efficient, (2) cost-effective, (3) confidential, and (4) capable of providing flexible solutions to complex problems. How to Request If the parties wish to mediate this case, they must file a Joint Mediation Request for Mediation with the Office of Administrative Hearings. A Joint Request for Mediation is included with this Mediation Notice. REGISTRAR OF CONTRACTORS OF THE STATE OF ARIZONA _________________________ Case No. _______________ COMPLAINANT,

v. JOINT REQUEST FOR MEDIATION _________________________ RESPONDENT.

REQUEST

The parties jointly request that this matter be referred to mediation in the Office of Administrative Hearings (OAH). ☐ This matter is set for hearing on __________________(date). ☐ This matter is not currently set for hearing. MEDIATION AGREEMENT By requesting this mediation and signing below, the parties understand, represent, and agree: 1. The parties are prepared to commence mediation and will be ready for mediation on _____________________(date); 2. The parties will participate in the mediation process in good faith; 3. This request for mediation is not intended to hinder or delay administrative proceedings; 4. No party will contend that the mediation limits the power of OAH and its administrative law judges to conduct an administrative hearing and issue decisions under A.R.S. §§ 41-1092 – 1092.12; 5. The parties will be courteous and respectful throughout the mediation process to all participants; 6. The mediation is completely voluntary and the principal purpose is to allow the parties a full and fair opportunity to discuss settlement; of 3 REGISTRAR OF CONTRACTORS 1700 W. Washington St. Suite 105 – PHOENIX, AZ 85007-2812 Telephone (602)542-1525 1-877-692-9762 7. The mediator may conduct joint and separate meetings with the parties and may suggest resolutions to the parties’ dispute, but the mediator has no authority to impose a settlement upon the parties; 8. The mediation process is confidential. Communications made, material created for or used during, and acts occurring during mediation are confidential and may not be discovered or admitted into evidence in any proceeding except as provided by A.R.S. § 12-2238; 9. The mediator is not subject to service of process or a subpoena to produce evidence or to testify regarding any evidence or occurrence relating to the mediation except as provided in A.R.S. § 12-2238(C); 10. Neither the mediator, nor the Registrar of Contractors, nor the Office of Administrative Hearings is subject to civil liability for any act or omission in connection with any mediation service or activity except for acts involving

intentional misconduct or reckless disregard of a substantial risk of injury to the rights of others; 11. Throughout the mediation process, each party must have a representative present who will have full settlement authority to settle all claims at issue in the administrative

proceeding. 12. The mediation process will terminate when: a. The parties reach settlement; b. The mediator determines that further efforts at mediation are no longer likely

to achieve a settlement; or c. One of the parties withdraws from mediation. _____________________________________ _______________________ Complainant (or representative) Date

_____________________________________ _______________________ Respondent (or representative) Date

of 3 REGISTRAR OF CONTRACTORS 1700 W. Washington St. Suite 105 – PHOENIX, AZ 85007-2812 Telephone (602)542-1525 1-877-692-9762 PREHEARING DISCLOSURE STATEMENT INSTRUCTIONS ***DO NOT SUBMIT THESE INSTRUCTIONS WITH THE PREHEARING DISCLOSURE FORM***

ADMINISTRATIVE RULES A copy of the Arizona Administrative Code’s Rules for the Registrar of Contractors can be located on the Registrar’s Website.

PREHEARING DISCLOSURE REQUIREMENT Under A.A.C. R4-9-118(A), before a hearing, the parties must prepare a disclosure statement. The disclosure statement must contain: • A list of all the witnesses the party will call to testify, including the witnesses’ contact information and a brief description of the subject matter of the witnesses’ expected testimony; and • A list of all the exhibits that the party will use at the hearing.

FILE PREHEARING DISCLOSURE STATEMENTS • The Prehearing Disclosure Statements and Exhibits may be submitted to the Arizona Office of Administrative Hearings using any of the following: • Electronically: https://portal.azoah.com/submission/ • In-Person or by Mail: 1740 West Adams Street, Lower Level, Phoenix, Arizona 85007

EXCHANGING DISCLOSURE STATEMENTS AND EXHIBITS Under A.A.C. R4-9-118(B) (effective November 5, 2017), a party to the hearing must serve on every other party and file with the Office of Administrative Hearings a copy of: • The disclosure statement; and, • Any exhibit that the party will use at the hearing. Service: The disclosure statement and exhibits must be served on all parties in accordance with Arizona Administrative Code R2-19-108 Filing Documents. Under A.A.C. R2-19-108, service is completed by: • Personal delivery; • 1st class, certified or express mail; or • Facsimile. Timing: The disclosure statement and the exhibits must be served and filed not less than seven calendar days before the date of the hearing. Under A.A.C. R2-19-108, a document is served on a party: • On the date it is personally served; • Five days after it is mailed by express or 1st class mail; • On the date of the return receipt if it is mailed by certified mail; or • On the date indicated on the facsimile transmission.

CONSEQUENCES FOR FAILING TO DISCLOSE Under A.A.C. R4-9-108(C), if a witness or an exhibit is not timely disclosed as required the rules, and good cause for the failure to disclose is not shown, then the administrative law judge may: • Order that certain witnesses or exhibits not be used at the hearing; • Order that a particular fact is or is not established for the record; or, • Order that a charge, a defense, a claim, or some portion thereof, be dismissed.

Form RC-L-800A Prehearing Disclosure Statement Rev. 10/08/2019 Instructions Form PREHEARING DISCLOSURE STATEMENT FORM RC-L-800A

PART 1: WITNESS LIST DOCKET NO. Under A.A.C. R4-9-118(A), before a hearing, a party must prepare a disclosure statement containing a list of all the witnesses the party will call to testify, including the witnesses’ contact information and a brief description of the subject matter of the witnesses’ expected testimony. If you need additional space to list all witnesses, complete and attach additional Witness Lists. Example 1. Name 2. Telephone Number 3. Email Address

John Doe (123) 456-7890 [email redacted] 4. Subject Matter of Expected Testimony

John Doe will testify regarding the poor workmanship and poor installation of the Garage Door. Mr. Doe will also testify regarding the invoices and change orders for the project.

Witness 1. Name 2. Telephone Number 3. Email Address

4. Subject Matter of Expected Testimony

Witness 1. Name 2. Telephone Number 3. Email Address

4. Subject Matter of Expected Testimony

Witness 1. Name 2. Telephone Number 3. Email Address

4. Subject Matter of Expected Testimony

Witness 1. Name 2. Telephone Number 3. Email Address

4. Subject Matter of Expected Testimony

Form RC-L-800A Prehearing Disclosure Statement Rev. 1/15/2019 Page 1 of 3 PART 2: EXHIBIT LIST DOCKET NO. Under A.A.C. R4-9-118(A), before a hearing, a party must prepare a disclosure statement containing a list of all the exhibits that the party will use at the hearing. Note: All exhibits listed below must be provided to all parties to the hearing. See A.A.C. R4-9-118(B). If you need additional space to list all witnesses, complete and attach additional Exhibit Lists. Example Contract for new garage door. Invoice #10001 – Cost for garage door replacement.

Exhibit Exhibit Name

Form RC-L-800A Prehearing Disclosure Statement Rev. 1/15/2019 Page 2 of 3 PART 3: ACKNOWLEDGEMENT & SIGNATURE I certify that the above information is true and correct and that I will serve a copy of this disclosure statement and any exhibits listed in Part 2 to all parties to the hearing in accordance with A.A.C. R4-9-118. I acknowledge and understand that if I fail to properly disclose a witness or exhibit, the administrative law judge may: • Order that certain witnesses or exhibits not be used at the hearing; • Order that a particular fact is or is not established for the record; or, • Order that a charge, a defense, a claim, or some portion thereof, be dismissed.

I am the (check one):  Complainant  Respondent Docket No.

Print Name Signature Date

Form RC-L-800A Prehearing Disclosure Statement Rev. 1/15/2019 Page 3 of 3